OM-J

Quarter-turn (Part-turn) Electric Actuators / OM Series
OM-J

  • Torque: 80 Nm/708 in-lb
  • Motor Power: 5 W
  • Manual Override: Lever
  • Mounting Flange: ISO 5211 F05/F07
  • Speed: 130 sec/90° (110VAC@60 Hz, 30% duty cycle)
  • Weight: 3 kg/6.6 lb
Item OM-J
Torque (Nm) 80
Torque (in-lb) 708
Size of Output Drive (mm) 🟐17
Depth of Output Drive (mm) 20
Flange (ISO 5211) F05 / F07
Run Time (sec / 90°) 130
Manual Override Lever
Weight (kg) 3
Weight (lb) 6.6

Enclosure

  • Polyester powder-coated aluminum alloy.
  • NEMA type 4X, IP66 & IP67, intended for outdoor use.
  • ISO 12944-2 Corrosivity category C3.

Motor

  • Insulation class F
  • Built-in thermal protector prevents the motor from overheating and burnout.
  • Thermal trip temperature:
    AC motor: 125±5℃ (257±9℉)

Duty Cycle

  • Standard: 30% duty cycle
  • The extended duty option is not applicable.

Position Indication

  • A mechanical position indicator is located on the top of the actuator.

Gear Train

  • High-alloy steel planetary gears are used, and a self-locking function is provided.
  • The gears are lubricated for life with high-temperature grease.

Conduit Entry

  • Standard: 1/2" PS
  • Optional: 1/2" PF, 1/2" NPT, M20

Voltages

  • 24V AC
  • 110 - 120V AC

Travel Angle

  • Standard: 0° to 90°

Operating Condition

  • Ambient temperature: -30℃ to +65℃ (-22℉ to +149℉)
  • Relative humidity: 30% to 95%
  • CE
  • CSA

Anti-condensation Heater

The heater warms actuators to prevent lubricant freezing and moisture damage.
● Not recommended if ambient temperature exceeds 35℃ (95℉).
● For large day/night or seasonal temperature variations, use with a thermostat is recommended.

Heater Thermostat

Heater thermostat switches off the heater when the internal temperature of actuators is higher than 25±5˚C (77±9˚F).

Auxiliary Limit Switches

Actuators come standard with two limit switches, LS1 for fully-open and LS2 for fully-closed positioning. Two auxiliary limit switches (LS3 & LS4) are optional for fully-open and fully-closed position feedback.

Potentiometer

Recommended to use with a floating control actuator to output signal for position indication.
● Two resistance values, 1k ohm or 5k ohm for selection.