| Item | LE-250 |
|---|---|
| Thrust (kgf) | 250 |
| Thrust (lbf) | 550 |
| Thrust (kN) | 2.45 |
| Flange (ISO 5210) | F07 |
| Max. Stroke (mm) | 50 |
| Max. Stroke (inch) | 2 |
| Run Speed (mm/sec) | 0.46 |
| Run Speed (inch/sec) | 0.018 |
| Manual Override | Hand-Wheel |
| Weight (kg) | 10.5 |
| Weight (lb) | 23.5 |
| Marking | Ambient Temperature |
|---|---|
| Ex db IIB T4 Gb | -30°C ~ +70°C (-22°F ~ +158°F) |
| Ex db IIB T4 Gb | -30°C ~ +70°C (-22°F ~ +158°F) |
In accordance with IEC 60079-0, IEC 60079-1, IEC60079-31
China Explosion-proof Certification - CNEx / CCC| Marking | Ambient Temperature |
|---|---|
| Ex db IIB T4 Gb | -30°C ~ +70°C (-22°F ~ +158°F) |
| Ex tb IIIC T130 °C Db | -30°C ~ +70°C (-22°F ~ +158°F) |
In accordance with IEC 60079-0, IEC 60079-1, IEC60079-31
EU Explosion-proof Certification - ATEX| Directive | Marking | Ambient Temperature |
|---|---|---|
| ATEX II 2GD | Ex db IIB T4 Gb | -30°C ~ +70°C (-22°F ~ +158°F) |
| ATEX II 2GD | Ex tb IIIC T130°C Db | -30°C ~ +70°C (-22°F ~ +158°F) |
In accordance with IEC 60079-0, IEC 60079-1, IEC60079-31
International Explosion-proof Certification - IECEx| Marking | Ambient Temperature |
|---|---|
| Ex db IIB T4 Gb | -30°C ~ +70°C (-22°F ~ +158°F) |
| Ex tb IIIC T130 °C Db | -30°C ~ +70°C (-22°F ~ +158°F) |
In accordance with IEC 60079-0, IEC 60079-1, IEC60079-31
CSA North American Hazardous Area Certification - Zone System| Code | Class | Permitted Zone | Type of Protection | Group | Temperature Class | Ambient Temperature |
|---|---|---|---|---|---|---|
| AEx / Ex | I | 1 | db | IIA, IIB | T4 | -30°C~+70°C(-22°F~+158°F) |
| AEx / Ex | II | 21 | tb | IIIA,IIIB,IIIC | T130°C | -30°C~+70°C(-22°F~+158°F) |
In accordance with CAN / CSA-C22.2 No. 60079-0, CAN / CSA-C22.2 No. 60079-1, CAN / CSA-C22.2 No. 60079-31, UL 60079-0, UL 60079-1, UL 60079-31
A space heater can increase the internal temperature and keep dry inside actuator to avoid the freezing lubricant and moisture causing actuator failure under low temperature or high humidity. Heater is not recommended if the ambient temperature is above 35 degrees℃ (95 degrees℉). However, when the temperature varies much from day to night or between summer and winter, heater and thermostat (25±5 degrees℃ / 77±41 degrees℉) are recommended.
The option can switch the heater off when the temperature inside the actuator is over 25°C / 77°F.
An external switch is applied to provide either two-position or floating control to the actuator.
1. Thrust (kg)
2.Voltage
3.Control Method