Our explosion-proof linear electric actuators provide thrust ranges of 250 to 2,000 kgf (550 ~4410 lbf). All models are equipped with modulating controllers and are suitable for globe valves, gate valves and linear travel devices. They can be applied for HVAC and industrial purposes, especially for steam and high temperature employments.
LE series explosion-proof electric linear actuators are structured as flame-proof and combustible dust-proof. The directive and standards marking are: II2GD Ex db IIB T4 Gb, Ex tb IIIC T130°C Db, Ta= -30°C to +70°C (ATEX), -30°C to +65°C (CSA). They are control devices for valves and can be used in places, classified as Zone 1 or Zone 2, containing Group IIA and Group IIB gases, Zone 21 or Zone 22, containing combustible dust atmospheres or a mixture of explosive gas atmospheres and combustible dust atmospheres. Temperature groups T1 to T4.
Model | Thrust (kgf) | Thrust (lbf) | Thrust (kN) | Flange (ISO 5210) | Max. Stroke (mm) | Max. Stroke (inch) | Run Speed (mm/sec) | Run Speed (inch/sec) | Manual Override | Weight (kg) | Weight (lb) |
---|---|---|---|---|---|---|---|---|---|---|---|
![]() LE-250 |
250 | 550 | 2.45 | F07 | 50 | 2 | 0.46 | 0.018 | Hand-Wheel | 10.5 | 23.5 |
![]() LE-500 |
500 | 1100 | 4.9 | F07 | 50 | 2 | 0.46 | 0.018 | Hand-Wheel | 10.5 | 23.5 |
![]() LE-1000 |
1000 | 2205 | 9.805 | F10 | 100 | 4 | 0.46 | 0.018 | Hand-Wheel | 31.5 | 69.5 |
![]() LE-2000 |
2000 | 4410 | 19.615 | F10 | 100 | 4 | 0.46 | 0.018 | Hand-Wheel | 31.5 | 69.5 |
Note: Run Speed is specified under 110 VAC / 60 Hz modulating control with 75% duty cycle.