OM-8 quarter turn actuator
Model | Torque | |
---|---|---|
N‧m | in‧lb | |
BM-2 | 120 | 1065 |
OM-A | 50 | 445 |
OM-AM | 50 | 445 |
OM-1 | 35 | 310 |
OM-F | 65 | 575 |
OM-J | 80 | 708 |
OM-2 | 90 | 800 |
OM-G | 120 | 1065 |
OM-3 | 150 | 1330 |
OM-H | 300 | 2655 |
OM-4 | 400 | 3540 |
OM-5 | 500 | 4430 |
OM-6 | 650 | 5755 |
OM-7 | 1000 | 8855 |
OM-8 | 1500 | 13280 |
OM-9 | 2000 | 17710 |
OM-10 | 2500 | 22140 |
OM-11 | 3000 | 26565 |
OM-12 | 3500 | 31000 |
OM-13 | 4500 | 40000 |
Weight | Flange Type | Shaft | Depth of Shaft | Manual Override | |||
---|---|---|---|---|---|---|---|
kg | lb | ISO 5211 | mm | inch | mm | inch | |
5.5 | 13 | F07 | 22 | 0.886 | 35 | 1.377 | N/A |
3 | 6.6 | F05/F07 | 17 | 0.669 | 20 | 0.787 | N/A |
3 | 6.6 | F05/F07 | 17 | 0.669 | 20 | 0.787 | Lever |
2 | 4.4 | F03/F05 | 14 | 0.551 | 17 | 0.669 | Lever |
11 | 25 | F07/F10 | 22 | 0.886 | 30 | 1.181 | Hand-Wheel |
3 | 6.7 | F05/F07 | 17 | 0.669 | 20 | 0.787 | Lever |
11 | 25 | F07/F10 | 22 | 0.886 | 30 | 1.181 | Hand-Wheel |
11 | 25 | F07/F10 | 22 | 0.886 | 30 | 1.181 | Hand-Wheel |
11 | 25 | F07/F10 | 22 | 0.886 | 30 | 1.181 | Hand-Wheel |
17 | 38 | F07/F10 | 22 | 0.886 | 30 | 1.181 | Hand-Wheel |
20 | 45 | F10/F12 | 36 | 1.417 | 40 | 1.574 | Hand-Wheel |
20 | 45 | F10/F12 | 36 | 1.417 | 40 | 1.574 | Hand-Wheel |
20 | 45 | F10/F12 | 36 | 1.417 | 40 | 1.574 | Hand-Wheel |
32 | 71 | F12 or F14 | 35 | 1.377 | 60 | 2.362 | Hand-Wheel |
32 | 71 | F12 or F14 | 35 | 1.377 | 60 | 2.362 | Hand-Wheel |
71 | 157 | F14 or F16 | 75 | 2.952 | 100 | 3.937 | Hand-Wheel |
71 | 157 | F14 or F16 | 75 | 2.952 | 100 | 3.937 | Hand-Wheel |
72 | 159 | F14 or F16 | 75 | 2.952 | 100 | 3.937 | Hand-Wheel |
72 | 159 | F14 or F16 | 75 | 2.952 | 100 | 3.937 | Hand-Wheel |
106 | 234 | F16/F25 | 72 | 2.834 | 110 | 4.33 | Hand-Wheel |
- CE
- CSA
- RoHS
Space heater
A space heater can increase the internal temperature and keep dry inside actuator to avoid the freezing lubricant and moisture causing actuator failure under low temperature or high humidity. Heater is not recommended if the ambient temperature is above 35℃/95℉. However, when the temperature varies much from day to night or between summer and winter, heater and thermostat (25±5℃/77±9℉) are recommended.

Heater thermostat
The option can switch the heater off when the temperature inside the actuator is over 25℃/77℉.

Additional limit switches
The standard model equips with the 1st & 2nd switches for fully-open and fully-closed. The option consists of the 3rd & 4th auxiliary switches which provide dry contacts for fully-open and fully-closed.

OM-2~OM-13,OM-F,OM-G
Current position transmitter
The option can provide 4-20mA output signal for position indicator and etc.

OM-2~OM-13,OM-F,OM-G The picture is based on AC 110/220V
Modulating controller
Actuator can be operated according to input signal and provide the output signal for indicator. Input signal : 4-20mA, 1-5V, 2-10V. Output signal : 4-20mA, 2-10V.

OM-2~OM-13,OM-F,OM-G
The pictures are based on AC 110/220V
75% duty cycle (IEC standard)
The option is suggested for higher starting frequency.

OM-2~OM-8:75%duty cycle
The picture is based on AC 110/220V
Potentiometer unit
The option can be ordered with On/Off actuators.
The selection has 1k or 5k ohm resistance values.
It provides feedback signal for position indicator.

OM-2~OM-13(1KΩ or 5KΩ)
Local control unit
The option can be used in filed control. It provides Local/Remote selection switches and Open/Close selection switches. It is available for OM-2 to OM-13,OM-F,OM-G actuators and must be ordered with actuator.

Torque switches
The option can provide over-load protection. It is available for OM-2 to OM-13,OM-F,OM-G actuators, and must be ordered with actuator.

Time Delay Controller
The option can adjust the actuator speed (running time) from standard to 30s, 60s and so on (Max. 200s) according to user’s need. It is available for OM-2 to OM-13, AC 220V,1-PH and OM-2 to OM-8, 110VAC actuators.

Chain wheel
The option can convert the hand-wheel override to a chain driven override in application of actuator mounted at a distance above the floor. It is available for OM-2 to OM-13,OM-F,OM-G actuators.

Wiring box
the option can be connected all wires by the user without removing actuator cover and it is available for OM-2 to OM-13,OM-F,OM-G actuators.

Coupling wiring
when a set of control wire or switch needs to control two or more actuators at the same time.

OM-2~OM-13,OM-F,OM-G
Communication Protocols
Modbus RTU RS485
Available for:
※OM-2 to 6, F, G, H 110-120VAC/1-PH, 30% duty cycle
※OM-2 to 8, F, G, H 220-240VAC/1-PH, 30% duty cycle
※OM-2 to 8, F, G, H 110-240VAC/1-PH, 75% duty cycle
※OM-9 to 13, 110-240VAC/1-PH, 50% duty cycle
Thermal Insulation Blanket
The combination of quarter-turn electric actuators with a Thermal Insulation Blanket is designed to remove and re-install easily. It makes the actuator run smoothly even in high temperature environment.
Working conditions:
※ Withstand two hours at 250°C (482°F).
※ Withstand one hour at 300°C (572°F).
Available for OM-A, OM-AM, OM-1 to OM-8 floating control.