Product Name : S500
Description
Max Torque:50 N.m/445 lb.in
Standard Weight:27 kg/60 lb
W / Manual Override Weight:37 kg/82 lb
Mounting Flange(ISO 5211):F07

Standard Capability :

  • Duty cycle rating:50% (Conform to IEC standard).
  • Two-position control.

Ambient Temperature Range :

  • Temperature:-30℃~+65℃/-22℉~+149℉
  • Humidity:30%~95%

Enclosure :

  • IP67、NEMA 4X:Water-proof and dust-proof enclosure.
  • Material:Dry powder coating aluminum alloy.

Lubrication :

  • Gear trains have been already lubricated sufficiently with anti-high temperature lubricant at the factory.

Position Indicator :

  • All models have continuous mechanism position indicator on the top of actuator cover.

Various voltage :

  • AC/DC 24V
  • AC 110/220V,1-Phase
  • AC 220/380/440V,3-Phase

Conduit entrance :

  • Standard:1/2"NPT
  • Optional:3/4"NPT,M20

Enclosure :

  • Nylon coating
  • E.D. coating
  • Epoxy coating
ModelMax TorquePower
(Watts)
WeightStandard Mounting
N.mlb.inStandardW / Manual 
Override
Mounting FlangeShaftDepth Of Shaft
KglbKglb(ISO 5211)mminchmminch
S500 50 443 50 27 60 37 82 F07 17 0.67 30 1.18
S1300 130 1151 130 57 126 74 163 F10 22 0.87 39 1.54
S2000 200 1771 130 95 209 135 298 F12 27 1.06 45 1.77
S2600 260 2302 130 95 209 135 298 F12 N/27 1.06 45 1.77
  • CE
  • CSA
  • RoHS

 

Our company is a professional manufacturer of, Multi Turn Actuator, Prepackaged Pneumatic Ball Valves, Global Valves, Solenoid Actuators Diagram Globe Valve, Electric Rotary Actuator, Motorized Actuator, Ball Valve Electric Actuator providing with top quality.

Space heater

A space heater can increase the internal temperature and keep dry inside actuator to avoid the freezing lubricant and moisture causing actuator failure under low temperature or high humidity. Heater is not recommended if the ambient temperature is above 35℃/95℉. However, when the temperature varies much from day to night or between summer and winter, heater and thermostat (25±5℃/77±9℉) are recommended.

Heater thermostat

The option can switch the heater off when the temperature inside the actuator is over 25°C / 77°F.

Additional limit switches

The standard model equips with the 1st & 2nd switches for fully-open and fully-closed. The option consists of the 3rd & 4th auxiliary switches which provide dry contacts for fully-open and fully-closed.

S500 S1300-S2600

Current position transmitter

The option can provide 4-20mA output signal and suit for two-position control units.

The picture is based on AC 110/220V

Floating controller

The actuator can be controlled by external controller to open, close and stop at any position between 0 and 90 degree and will fail clockwise to the end position on loss of power. (Based on the standard running direction that the actuator fails clockwise on loss of power.)

The picture is based on AC 110/220V

Modulating controller

Actuator can be operated according to input signal and provide the output signal for feedback.

Input signal:4-20mA,1-5V,2-10V

Output signal:4-20mA,2-10V

The picture is based on AC 110/220V

Operating direction

Standard : Fail clockwise on loss of power.

Optional : Fail counter-clockwise on loss of power.

Manual override

Potentiometer unit (1K or 5K)

The option can be ordered with two-position control actuators. The selection has 1k or 5k ohm resistance values. It provides feedback signal for position indicator.