Product Name : S-3600 spring return actuator
Description
Torque: 360 Nm / 3185 in-lb
Standard Unit Weight: 103 kg / 228 lb
Weight of S-3600 with Optional Manual Override: 152 kg / 336 lb
Mounting Flange:ISO 5211 F12

Standard Features

  • Duty rating: 50% duty cycle at -40℃ to 40℃、30% duty cycle at 41℃ to 65℃.
  • ON-OFF (Two-position) control

Operating Condition

  • Ambient Temperature: -30℃ to +65℃ (-22℉ to +149℉)
  • Relative Humidity: 30% to 95%

Enclosure 

  • IP68 (7m, 72 hrs), NEMA 4X / 5
  • Dry powder coated aluminum alloy

Lubrication 

  • Gear trains have been already lubricated sufficiently with High-Temp grease at the factory.

Position Indication

  • Visual mechanical position indicator.

Power Supply Voltages 

  • AC/DC 24V (NOT available with floating or modulating control)
  • AC 110V, 220V - 1 Phase (NOT available with floating or modulating control)

Conduit Entry

  • Standard:2 x 1/2" NPT
  • Optional:2 x 3/4" NPT, 2 x M20

Model  TorqueMotor
Power
(W)
WeightMounting Interface
  Nm  in-lb  Standard   With Manual Override  Flange  Output Drive  Output Drive Depth
KglbKglb ISO 5211 mminchmminch
S-500 50 445 50 27 60 37 82 F07 17 0.669 30 1.181
S-1300 130 1150 130 57 126 77 170 F10 22 0.866 41 1.614
S-2000 200 1770 130 93 205 131.5 290 F12 27 1.062 45 1.772
S-2600 260 2300 130 95 210 133.5 295 F12 27 1.062 45 1.772
S-3600 360 3185 130 103 228 152 336 F12 36 1.417 43 1.693
  • CE
  • CSA

proimages/product/S/SH36S01A-en-2023-Jul.jpg

Space heater

A space heater can increase the internal temperature and keep dry inside actuator to avoid the freezing lubricant and moisture causing actuator failure under low temperature or high humidity. Heater is not recommended if the ambient temperature is above 35℃/95℉. However, when the temperature varies much from day to night or between summer and winter, heater and thermostat (25±5℃/77±9℉) are recommended.

proimages/加熱器.png

Heater thermostat

The option can switch the heater off when the temperature inside the actuator is over 25±5°C (77±9°F).

Additional limit switches

The standard model equips with the 1st & 2nd switches for fully-open and fully-closed. The option consists of the 3rd & 4th auxiliary switches which provide dry contacts for fully-open and fully-closed.

proimages/options/pro-39.jpg

Operating direction

Standard : Fail clockwise on loss of power.

Optional : Fail counter-clockwise on loss of power.

proimages/options/s500-3600-1-e.jpg

Manual override

proimages/options/s500-3600-2-e.jpg